- Condenser tubes. Specifications : The condenser is salt water cooled, two pass, divided waterbox surface condenser, with an integral full flow circulating water reversal system. The condenser has a total of 8,208, 1.0" OD, 18 gauge, aluminium brass (ASTM B111 C68700), main conden-sing tubes. The overall tube length is 35' 2 3/8". - Sootblowers. They use steam for sootblower media in all their boilers. They use sootblowers in 3 locations : (a) Wall blowers - furnace walls to remove slag/ash (b) Retractable blowers - convection pass, super-heater, re-heater, econo- mizer. (c) Fixed swing sootblower or rotary with multiple nozzles - Lungstrom rotary air heaters. |